When an incident reaches the plant, safety comes before evidence. A checklist for ICS and OT incidents: who can stop the process, engineering on the team, no scanning of fragile devices, HMI, historian and engineering-workstation evidence, IT/OT boundary isolation, manual operations and restoring logic from known-good.

Template & sample only · See the sample ↓ — a structured starting point with sample content, not legal, audit, certification or investment advice.

Template & sample only. Generated from a PlayCISO template as a starting point: it is not legal, audit, certification, investment or professional advice. Review, adapt and validate it for your organisation before you rely on it.You are looking at sample data. Replace it with your own details below — the document regenerates as you type and your copy is saved in this browser.

A response checklist for incidents that touch industrial control systems, where safety and continuity come before evidence. It starts with who can stop the process, brings engineering in before anyone touches a controller, contains at the IT/OT boundary, preserves HMI, historian and engineering-workstation evidence without scanning fragile devices, restores logic only from known-good copies, and ends with sector and national reporting. Mark each step and the page builds an incident record.

Also as
Response steps complete (weighted)
66/100
17 of 24 items assessed
Safety confirmed
Yes
Fragile-device rule
In force
Material steps still open
4
1. Safety first
3/4 done
2. Bring in engineering and operations
3/3 done
3. Contain at the IT/OT boundary
3/4 done
4. Preserve OT evidence
2/5 done
5. Recover from known-good
0/5 done
6. Report and learn
0/2 done

Your context

1. Safety first

In an industrial incident the first question is not "what did the attacker do" but "is the process safe, and who can stop it".

  • Confirm who has authority to stop, slow or hand-run the process, and that they are reachable nowmaterial

  • Ask operators whether the process is behaving normally: alarms, setpoints, valve and pump states, HMI values that do not match the fieldmaterial

  • Confirm the safety instrumented system (SIS) is healthy and has not been bypassed, put into program mode or changedmaterial

  • Check manual operation is possible for the critical units: staff, procedures, local controls, and how long it can be sustained

2. Bring in engineering and operations

  • Form a joint team: incident commander, control engineers, operations, process safety, IT security and the OT vendor or integrator where neededmaterial

  • Freeze all non-emergency changes to control systems and suspend vendor remote sessions until reviewed

  • Agree a communication path to the control room that does not depend on systems that may be compromised (radio, phone tree)

3. Contain at the IT/OT boundary

Contain at the boundaries first; the plant floor is the last place to cut cables.

  • Decide whether to cut or restrict the IT/OT connection (DMZ firewall rules, remote access), with operations agreeing what will stop workingmaterial

  • Disable remote access into OT: vendor VPNs, jump hosts, remote-desktop tools, cellular modemsmaterial

  • Do not run active scans, vulnerability scanners or aggressive endpoint tools against controllers, safety systems or legacy devicesmaterial

  • Contain inside OT by zone and conduit where needed, following the plant network design rather than ad-hoc unplugging

4. Preserve OT evidence

Collect what you can without touching the process.

  • Preserve the engineering workstations: isolate from the network but keep powered on; capture memory and disk with the control engineer presentmaterial

  • Preserve HMI and SCADA server logs, alarm and event journals, and operator action logs before they roll over

  • Preserve historian data for the incident window: process values, gaps and any edits or deletions

  • Pull the running logic and configuration from controllers (read-only) and compare with the last known-good version

  • Keep network captures and firewall logs from the IT/OT boundary and inside OT

5. Recover from known-good

  • Restore logic and configuration only from verified known-good copies (offline backups, version-controlled projects), checked by hash or comparisonmaterial

  • Rebuild engineering workstations, HMIs and historians from clean media; do not reuse a machine that may hold attacker tools

  • Change OT passwords and shared accounts, including default and vendor accounts, before reconnecting anything

  • Reconnect IT to OT only when the IT side is shown to be clean, with tighter rules than before and monitoring in placematerial

  • Run a staged restart and functional test with operations and safety sign-off before full production

6. Report and learn

  • Report to the right authorities: national CERT or CISA, sector regulator, and any mandatory reporting regime for critical infrastructureCISAmaterial

  • Report any safety or environmental impact through the normal safety and environmental reporting routes as well

  • Hold a joint IT/OT post-incident review and feed the findings into zones and conduits, remote access and backup of logicIEC 62443

Loading…

Sample report · illustrative data

Sample record: OT incident response checklist

Example record for an invented water-treatment and bottling site part-way through an incident that began as ransomware on the IT network.

Record header (profile fields)

Organisation and site
Riverside Utilities, North treatment and bottling plant
Incident reference
OT-2026-007
Person with authority over the process
Night shift supervisor, then plant manager
What happened
Corporate file servers encrypted overnight; the historian and one engineering workstation in the DMZ were also affected

Checklist rows (excerpt)

SectionStepStatus
1. Safety firstConfirm who has authority to stop, slow or hand-run the process, and that they are reachable nowDone
3. Contain at the IT/OT boundaryDisable remote access into OT: vendor VPNs, jump hosts, remote-desktop tools, cellular modemsDone
3. Contain at the IT/OT boundaryContain inside OT by zone and conduit, following the plant network design rather than ad-hoc unpluggingIn progress
5. Recover from known-goodReconnect IT to OT only when the IT side is shown to be clean, with tighter rules and monitoringNot done

Summary lines the tool calculates

  • Safety confirmed: Yes only once authority, process state and safety-system health are all marked done.
  • Fragile-device rule: In force once "no active scans against controllers or safety systems" is done.
  • Material steps still open: a count of the highest-weight steps not yet done.
  • Per-section progress, such as "2/3 done".

Made-up example data. Your own run uses your inputs. Downloads of the full report need Pro.

TL;DR

What this template gives you

4 points
  • Six phases: safety first, bring in engineering and operations, contain at the IT/OT boundary, preserve OT evidence, recover from known-good, report and learn.
  • Built around rules IT playbooks miss: operations decides on the process, never disable a safety system to contain, never scan fragile controllers, and keep engineering workstations powered on for evidence.
  • Sample values show a fictional utility where ransomware on IT reached the historian. Replace them with your own and the page builds an incident record.
  • Reporting guidance is phrased by regime and sector; check deadlines with counsel for your country.

Frequently asked questions

How is OT incident response different from IT incident response?

The priorities are reversed. In IT you often trade availability for containment and evidence. In OT, stopping or disturbing the process can injure people, damage equipment or harm the environment, so safety and controlled operation come first and evidence collection works around them. Operations and control engineers decide what happens to the process; security advises.

Should we scan the OT network to find the attacker?

Not with active scanners. Many PLCs, RTUs and older devices can fault or stop when scanned. Use passive network monitoring, existing OT security sensors, logs from firewalls and the engineering workstations, and vendor-approved tools used with the control engineer present.

Should we disconnect the plant from the IT network?

Often yes, and early, when the attack is on the IT side. But know what the link carries first: production reporting, recipe or batch downloads, licence servers, time sync and remote vendor support may stop. Agree the consequences with operations, then cut decisively. The Safe-to-Isolate Matrix helps plan this per asset.

Who do we report an OT incident to?

It depends on country and sector. In the US, CISA takes reports from critical infrastructure owners and some sectors have their own rules. In the EU, entities in scope of NIS2 send an early warning within 24 hours, a notification within 72 hours and a final report within one month. Safety and environmental incidents also go through their usual routes. Check with counsel.

Is this a finished document I can rely on?

No. Every tool in this suite is a template with sample content. It gives you a structured, editable starting point and generates a document from your own answers, but it is not legal, audit, certification, investment or professional advice. Review and adapt the output, and have it checked by the appropriate specialist before you rely on it.

Who can use it?

The page and sample are public. Customising the template is Pro; a free account gets 3 runs in total, shared across every Pro tool, and the generated document is free to view on the page. Download is Pro: downloading or copying the document (Word, PDF, Markdown, CSV) is never part of the free runs. Pro is $5/month or $40/year. Your work is saved in your own browser.

The tools people use most on PlayCISO.

All tools